CONTROL PARTS | AVR (Automatic Voltage Regulator) |
|
|
|
|
MODEL : 635 |
|
FUNCTION 1. Single Phase half-wave rectification 2. A/S support 3. Selection switch for generator capacity is included 4. Selection switch 50Hz~60Hz frequency is included 5. Low Frequency Protect Circuit is included 6. Anti Over Voltage Circuit is included 7. Noise filter (Input power type) is included
SPEC. 1. Output : 63Vdc, 5A 2. Input power : Single Ph 220Vac(190~277), 50/60Hz 3. Sensing Input :Single Phase,190~520Vac, 50/60Hz 4. Size(mm) : W95*H160 *D37 5. distance[attach](mm) : W60*H150, 5¢ x4 6. Weight : 530g |
|
| |
|
|
MODEL : 631 |
|
FUNCTION 1. Single Phase half-wave rectification 2. A/S support 3. Selection switch for generator capacity is included 4. Selection switch 50Hz~60Hz frequency is included 5. Low Frequency Protect Circuit is included 6. Anti Over Voltage Circuit is included 7. Noise filter (Input power type) is included
SPEC. 1. Output : 63Vdc, 10A 2. Input power : Single Ph 220Vac(190~277), 50/60Hz 3. Sensing Input :Single Phase,190~520Vac, 50/60Hz 4. Size(mm) : W95*H160 *D37 5. distance[attach](mm) : W60*H150, 5¢ x4 6. Weight : 530g |
|
| |
|
|
MODEL : 63P |
|
FUNCTION 1. Single Phase half wave rectification 2. Anti-humid and vibration by molding treatment 3. Select S/W for 50/60Hz is included 4. Selection switch for generator capacity is included 5. Low Frequency Protect Circuit is included 6. Anti Over Voltage Circuit is included 7. Noise filter (Input power type) is included
SPEC. 1. Output: 63Vdc, 5A 2. Input Power : Single Ph. 220Vac, 50/60Hz 3. Sensing Input : Single Ph, 190~520Vac, 50/60Hz 4. Size (mm) : W95*H160 *D37 5. distance[attach](mm) : W60*H150, 5¢ x4 6. Weight : 360g |
|
| |
|
|
MODEL : FC1 |
|
FUNCTION 1. Single Phase full wave rectification 2. Parallel Running Function 3. Select S/W for 50/60Hz is included 4. Select S/W for Generator capacity is included 5. Low Frequency Protect Circuit is included 6. Detect Over voltage output 7. Volt control is available extra controller 8. Extra Huse for semicon protect is included 9. Possible Input power from PMG or auxiliary winding
SPEC. 1. Output : 125Vdc, 6A 2. Input PW : Single Ph 220Vac(190~277),50~125Hz 3.Detached input :Single Ph,190-520Vac, 50/60Hz 4. Size (mm) : W140*H200 *D40 5. distance[attach](mm) : W90*H190, 5¢ x4 6. Weight : 1.35Kg |
|
| |
|
|
MODEL : FC2 |
|
FUNCTION 1. Single Phase full wave rectification 2. Select S/W for 50/60Hz is included 3. Select S/W for Generator capacity is included 4. Low Frequency Protect Circuit is included 5. Detect Over voltage output 6. Anti-humid and vibration by molding treatment 7. Possible Input power from PMG or auxiliary winding
SPEC. 1. Output : 125Vdc, 6A(750W) 2. Input PW : Single Ph 220Vac(190~277),50~125Hz 3. Sensing Input : Single ph,190-520Vac, 50/60Hz 4. Size (mm) : W140*H200 *D40 5. distance[attach](mm) : W90*H190, 5¢ x4 6. Weight : 690g |
|
| |
|
|
MODEL : CT1 |
|
FUNCTION 1. Single Ph half wave rectification for Catafila product 2. Anti Humid & vibration treatment by silicon coating 3. Detact 3 Pahse 220V 4. Parallel running circuit is included 5. Detact Over volt input signal 6. Low Frequency Protect Circuit is included
SPEC. 1. Input Power/Sensing : 3Phase 220Vac 2. Output : 63Vdc, 10A 3. Voltage Regulation : ±1% 4. Size(mm) : W130*H160 *D53 5. distance[attach](mm) : W60*H150, 5¢ x4 6. Weight : 700g | |